当前位置:首页 > 新闻中心灭火器维修步骤有哪些?

灭火器维修步骤有哪些?

来源:http://www.cx-fire.com/ 日期:2022-04-02

一、拆开
1、 Take apart
拆开救活器应选用的拆开办法,采纳必要的防护办法,在承认救活器内部无压力时,方可拆开救活器器头或阀门。
When disassembling the lifesaver, a safe disassembly method shall be adopted, and the necessary safety protection methods shall be adopted. When it is recognized that there is no pressure inside the lifesaver, the head or valve of the lifesaver can be disassembled.
二、救活器的收回处理
2、 Recovery treatment of lifeguard
从喷射过的干粉救活器内铲除的剩下救活剂应按ABC干粉和BC干粉救活剂别离进行收回贮存,这类救活剂不该用于再充装;从未喷射过的干粉救活器内铲除的救活剂应按救活器铭牌标志上标明的救活剂成别离离进行收回。经查验契合相关救活剂标准后,且无外来杂质,则可用于再充装。
The remaining resuscitants removed from the sprayed dry powder resuscitator shall be recovered and stored separately as ABC dry powder and BC dry powder resuscitants, which shall not be used for refilling; The resuscitation agent removed from the dry powder resuscitator that has never been sprayed shall be recovered separately according to the resuscitation agent indicated on the nameplate of the resuscitator. After inspection, it can be used for refilling if it meets the relevant standards of lifesaving agents and there are no foreign impurities.
三、水压实验
3、 Hydrostatic test
对承认不属于作废范围的救活器气瓶(筒体)、贮气瓶,或可不替换的器头(阀门),装有可间歇喷射设备的喷射软管组件,以及气瓶(筒体)与器头(阀门)的连接件等应逐一进行水压实验。对二氧化碳救活器的气瓶应逐一进行剩余变形率的测定。
川消
Hydraulic test shall be carried out one by one for the cylinder (cylinder) and storage cylinder of the lifesaving device, or the head (valve) that can not be replaced, the injection hose assembly equipped with intermittent injection equipment, and the connection between the cylinder (cylinder) and the head (valve). The residual deformation rate of the cylinder of carbon dioxide lifesaving device shall be measured one by one.
四、零部件替换
4、 Component replacement
修理组织应按原救活器出产企业的救活器装配图样和可替换零部件明细表进行部件替换,救活器气瓶(筒体)不行替换。替换的零部件应与原救活器出产企业供给的零部件的特性保持共同。
The repair organization shall replace the components according to the assembly drawing of the lifesaver and the list of replaceable parts and components of the original manufacturer of the lifesaver, and the cylinder (cylinder) of the lifesaver shall not be replaced. The replaced parts and components shall maintain the same characteristics as the parts and components supplied by the original lifeguard manufacturer.
经水压实验合格的气瓶(筒体),若外部有部分涂层掉落,但无锈蚀时,答应补加涂层,补加涂层应润滑、平坦、色泽共同,无气泡、流痕、皱纹等缺点。补加涂层不该掩盖铭牌。
For the cylinder (cylinder) that has passed the hydrostatic test, if part of the coating has fallen off but there is no corrosion, it is allowed to add additional coating. The additional coating should be lubricated, flat, common color, and free of bubbles, flow marks, wrinkles and other defects. The additional coating shall not cover up the nameplate.
每次修理时,下列零部件应作替换:密封片、圈、垫等密封零件;水基型救活剂;二氧化碳救活器的超压膜片。
During each repair, the following parts shall be replaced: sealing parts such as sealing plate, ring and gasket; Water based lifesaving agent; Overpressure safety diaphragm of carbon dioxide resuscitator.
五、再充装
5、 Refill
在进行救活剂再充装时,应按原救活器出产企业的要求进行操作。任何一种救活器均不该变更充装其他类型的救活剂。再充装的救活剂应与原救活器出产企业供给的救活剂的特性保持共同,用收回再利用的救活剂再重装时,应满足相关要求。
When refilling the lifesaving agent, it shall be operated according to the requirements of the original manufacturer of the lifesaving device. Any kind of lifesaving device should not be changed to fill other types of lifesaving agents. The refilled resuscitant shall maintain the same characteristics as the resuscitant provided by the original resuscitator manufacturer. When refilling with the recycled resuscitant, it shall meet the relevant requirements.
上一篇:水基型灭火器的优点和不足介绍!