1、室内消火栓应设在明显易于取用地点。栓口离地面高度为1.1m,其出水方向宜向下或与设置消火栓的墙面成90°角;
1. Indoor fire hydrants should be located in clearly accessible locations. The height of the hydrant mouth from the ground is 1.1m, and its water outlet direction should be downward or at a 90 ° angle with the wall where the fire hydrant is installed;
2、冷库的室内消火栓应设在常温穿堂或楼梯间内;
2. Indoor fire hydrants in cold storage should be located in room temperature corridors or stairwells;
3、川消室内消火栓的间距应由计算确定。高层工业建筑,高架库房,甲、乙类厂房,室内消火栓的间距不应超过30m;其他单层和多层建筑室内消火栓的间距不应超过50m。同一建筑物内应采用统一规格的消火栓、水枪和水带。每根水带的长度不应超过25m;
3. The spacing of indoor fire hydrants for Sichuan Xiaoxiao should be determined by calculation. The spacing between indoor fire hydrants in high-rise industrial buildings, elevated warehouses, Class A and Class B factories should not exceed 30m; The spacing between indoor fire hydrants in other single-story and multi-story buildings should not exceed 50m. Unified specifications of fire hydrants, water guns, and hoses should be used within the same building. The length of each water hose should not exceed 25m;
4、设有室内消火栓的建筑,如为平屋顶时,宜在平屋顶上设置试验和检查用的消火栓;
4. For buildings with indoor fire hydrants, if they are Flat roof, they should be equipped with fire hydrants for test and inspection on Flat roof;
川消
此外还要注意:
Also note:
1、室内消火栓应设在明显易于取用地点。栓口离地面高度为1.1m,其出水方向宜向下或与设置消火栓的墙面成90°角;
1. Indoor fire hydrants should be located in clearly accessible locations. The height of the hydrant mouth from the ground is 1.1m, and its water outlet direction should be downward or at a 90 ° angle with the wall where the fire hydrant is installed;
2、冷库的室内消火栓应设在常温穿堂或楼梯间内;
2. Indoor fire hydrants in cold storage should be located in room temperature corridors or stairwells;
3、室内消火栓的间距应由计算确定。高层工业建筑,高架库房,甲、乙类厂房,室内消火栓的间距不应超过30m;其他单层和多层建筑室内消火栓的间距不应超过50m。同一建筑物内应采用统一规格的消火栓、水枪和水带。每根水带的长度不应超过25m;
3. The spacing of indoor fire hydrants should be determined by calculation. The spacing between indoor fire hydrants in high-rise industrial buildings, elevated warehouses, Class A and Class B factories should not exceed 30m; The spacing between indoor fire hydrants in other single-story and multi-story buildings should not exceed 50m. Unified specifications of fire hydrants, water guns, and hoses should be used within the same building. The length of each water hose should not exceed 25m;
4、设有室内消火栓的建筑,如为平屋顶时,宜在平屋顶上设置试验和检查用的消火栓;
4. For buildings with indoor fire hydrants, if they are Flat roof, they should be equipped with fire hydrants for test and inspection on Flat roof;
5、高层工业建筑和水箱不能满足不利点消火栓水压要求的其他建筑,应在每个室内消火栓处设置直接启动消防水泵的按钮,并应有保护设施。
5. For high-rise industrial buildings and other buildings where water tanks cannot meet the water pressure requirements of unfavorable point fire hydrants, buttons should be installed at each indoor fire hydrant to directly start the fire pump, and protective facilities should be provided.