灭火器的日常维护
Daily maintenance of fire extinguishers
1.灭火器的检验和维修应由有关技术人员负责。
1. relevant technicians shall be responsible for the inspection and maintenance of fire extinguishers.
2.送修的每次灭火器数量不得超过计算单元配置的灭火器总数的1/4。在超过时,应选用同型号、同运行方式的灭火器代替,替代灭火器的灭火等级不得小于原配置灭火器。
2. the number of fire extinguishers sent for repair each time shall not exceed 1/4 of the total number of fire extinguishers configured in the calculation unit. In case of exceeding the limit, fire extinguishers of the same model and operation mode shall be used instead. The fire extinguishing grade of the substitute fire extinguishers shall not be less than that of the original ones.
3.检查或维修的灭火器应放置在原来的位置上。
3. the fire extinguishers inspected or repaired shall be placed in the original position.
4.需要维修和报废的灭火器应由灭火器生产企业或维修单位进行。
4. fire extinguishers that need to be repaired and scrapped shall be repaired by the fire extinguisher manufacturer or professional maintenance unit.
5.灭火器的结构、外观等应按附录C规定每月检查一次。
5. the structure and appearance of the fire extinguisher shall be inspected once a month according to the provisions of Appendix C.
6.下列场所配置的灭火器,每半个月应按附录C的要求进行检查。
6. the fire extinguishers equipped in the following places shall be inspected every half month according to the requirements of Appendix C.
7.等候(机、船)室、歌舞娱乐区、游艺厅等人员密集场所;
7. waiting room (aircraft and boat), song and dance entertainment area, recreation hall and other densely populated places;
8.堆场、储罐、石化设备区、加油站、锅炉房、地下室等。
8. storage yard, storage tank, petrochemical equipment area, gas station, boiler room, basement, etc.
9.日常巡检发现灭火器有挪动、缺少部件、或者灭火器配置位置的使用性质发生变化等情况时,应及时处置。
9. if the fire extinguisher is found to be moved, missing parts, or the nature of the use of the fire extinguisher configuration location changes during daily inspection, it shall be handled in time.
10.灭火器检查记录应予以保存。
10. fire extinguisher inspection records shall be kept.
灭火器的修理报废
Repair and scrapping of fire extinguishers
1.有机械损伤、明显锈蚀、灭火剂泄漏、打开使用过或符合其它维修条件的灭火器,应及时修理。
1. fire extinguishers with mechanical damage, obvious corrosion, fire extinguishing agent leakage, opened and used or meeting other maintenance conditions shall be repaired in time.
2.灭火器的保养期限应符合规定。
2. the maintenance period of fire extinguishers shall comply with the regulations.
3.维护和报废的依据是XF95-2015灭火器维修手册。
3. the basis for maintenance and scrapping is xf95-2015 fire extinguisher maintenance manual.
4.为确保灭火器使用和有效灭火,对灭火器进行检查、水压试验、灭火剂回收、零部件更换、再充装、报废与回收处置、质量检验等活动。
4. in order to ensure the safe use and effective fire extinguishing of fire extinguishers, carry out inspection, hydrostatic test, fire extinguishing agent recovery, parts replacement, refilling, scrapping, recycling and disposal, quality inspection and other activities on fire extinguishers.
5.灭火器使用者应按照GB50444的规定定期检查灭火器,发现符合维修要求的灭火器应及时送生产企业维修部门或其授权的维修机构进行维修。
5. the fire extinguisher user shall regularly inspect the fire extinguisher according to the provisions of gb50444, and send the fire extinguisher that meets the maintenance requirements to the maintenance department of the manufacturer or its authorized maintenance organization for maintenance in time.
川消
川消小编认为有下列情况时报废。
The products shall be scrapped in case of any of the following conditions.
1.灭火器从出厂日期算起,年满以下的,应当报废:
1. fire extinguishers shall be scrapped if they are less than years old from the date of delivery:
a)水基灭火器----6年;
a) Water based fire extinguishers - 6 years;
b)干粉灭火器--10年;
b) Dry powder fire extinguisher - 10 years;
c)洁净气体灭火器--10年;
c) Clean gas fire extinguisher - 10 years;
d)二氧化碳灭火器和贮气瓶--12年。
d) Carbon dioxide fire extinguishers and gas cylinders - 12 years.
2.发生下列情况之一的灭火器应当报废:
2. fire extinguishers in any of the following situations shall be scrapped:
标志模糊不清;
The sign is ambiguous;
气瓶(筒体)已烧坏;
The gas cylinder (cylinder) has been burnt out;
气瓶(筒体)有严重变形;
Serious deformation of gas cylinder (cylinder);
气瓶(筒体)外部涂层的脱落面积大于气瓶(筒体)总面积的三分之一;
The falling off area of the external coating of the gas cylinder (cylinder) is greater than one third of the total area of the gas cylinder (cylinder);
气瓶(筒体)外表面、连接部位、基座上有腐蚀凹坑;
There are corrosion pits on the outer surface, connecting parts and base of the gas cylinder (cylinder);
气瓶(筒体)有诸如锡焊、铜焊或补缀的修补痕迹;
The gas cylinder (cylinder) has repair marks such as tin welding, brazing or patching;
气瓶(筒体)内部有锈屑或内表面有腐蚀坑;
There are rust chips inside the cylinder (cylinder) or corrosion pits on the inner surface;
水基型灭火器筒体内的防腐涂层;
Anti corrosion coating in water-based fire extinguisher cylinder;
3.气瓶(筒体)连接线有损坏;
3. the connecting line of gas cylinder (cylinder) is damaged;
气瓶(筒体)水压试验不符合6.5.2规定;
The hydrostatic test of gas cylinder (cylinder) does not comply with the provisions of 6.5.2;
未遵守防火产品市场准入制度的;
Failing to comply with the market access system for fire protection products;
被不合法的维修机构修理;
Being repaired by an illegal maintenance organization;
法律或法规明确禁止使用的。
The use is expressly prohibited by laws or regulations.